Series: Siebel IP2016 – Siebel Enterprise Server Config Issues

Siebel IP2016 – Siebel Enterprise Server Config Issues

Siebel IP2016 – Siebel Enterprise Server Config Issues Part 1

This entry is part 1 of 6 in the series Siebel IP2016 – Siebel Enterprise Server Config Issues

Issue#1 Siebel Gateway Configuration failed with error SBL-GEN-05009 Environment: OS:Solaris Sparc 11 Siebel Version: 16 Issue: Siebel Gateway Name Server Configuration failed with error. Please see the files for details. Siebel.log

  Findings: I found a Oracle doc for the same error which says its a wizard bug but it should be fixed by now. As per doc, Check if Siebel…

Siebel IP2016 – Siebel Enterprise Server Config Issues Part 2

This entry is part 2 of 6 in the series Siebel IP2016 – Siebel Enterprise Server Config Issues

Issue#1 Unable to connect to the gateway server (SBL-GEN-05009) Environment: OS:Solaris Sparc 11 Siebel Version: 16 Issue: Siebel Gateway Configuration (2nd step of Enterprise Configuration) failed with below error.   Gaetway.log

 SRBroker.log

Findings: I found a Oracle doc for the same error which says host.conf file issue. By default the file host.conf, located in /etc/host.conf, has the “multi on” option set.…

Siebel IP2016 – Siebel Enterprise Server Config Issues Part 3

This entry is part 3 of 6 in the series Siebel IP2016 – Siebel Enterprise Server Config Issues

Issue#3 Siebel Gateway Configuration failed with error SBL-GEN-05009 Environment: OS:Windows Server 2012 R2 Siebel Version: 16 Issue: Siebel Gateway Name Server Configuration failed with error. Please see the files for details. Gateways name server windows services not created properly after this error. Cause: Installation User don’t have full admin rights to create windows services. Solution: We need to deactivate UAC (User Account…

Siebel IP2016 – Siebel Enterprise Server Config Issues Part 5

This entry is part 4 of 6 in the series Siebel IP2016 – Siebel Enterprise Server Config Issues

Issue#5 HTTP Error 500.0 Internal Server Error Environment: OS:Windows Server 2012R2 Siebel Version: 16 Issue: The Gateway and Siebel server is installed and running. The SWSE also installed without any issues. But accessing Thin application URL gives below error “HTTP Error 500.0 Internal Server Error The page cannot be displayed because an internal server error has occurred.” Cause: Microsoft Windows Server…